Anzeige
Anzeige
Anzeige

Multiplexed genetic profiling of human blood platelets using fluorescent microspheres

Journal: Thrombosis and Haemostasis
ISSN: 0340-6245
DOI: http://dx.doi.org/10.1160/TH08-05-0305
Issue: 2008: 100/5 (Nov) pp. 727-954
Pages: 929-936

Multiplexed genetic profiling of human blood platelets using fluorescent microspheres

Dmitri V. Gnatenko1, Wei Zhu2, Wadie F. Bahou1,3
1Department of Medicine, State University of New York, Stony Brook, New York, USA; 2Department of Applied Mathematics and Statistics, State University of New York, Stony Brook, New York, USA; 3Program in Genetics, State University of New York, Stony Brook, New York, USA

Summary

Human platelets have unique and reproducible mRNA profiles, with evidence for distinct profiles in haematopoietic stem cell disorders associated with thrombocytosis. Platelet transcript profiling is traditionally studied by microarray analysis, quantitative reverse transcription-PCR or serial analysis of gene expression, techniques that are labor- and technically-intensive.We have now applied a novel multiplex-based platform for quantitative transcript profiling of human platelets.Simultaneous quantification of 17 platelet transcripts was assayed using intact platelet- rich plasma or gel-filtered platelets lysed in vitro.Accurate and reproducible profiles could be obtained from as few as 5 X 107 platelets (a platelet mass corresponding to ~100 μl of whole blood), even for the low-abundant platelet transcripts. Correlation coefficients of this 17-member gene set to platelet Affymetrix microarrays were excellent (r2 = 0.949, p < 1 X 10–10), with no correlation to in kind-derived leukocyte profiles, highlighting the cell-specificity of the platform.These data demonstrate that transcript multiplexing using fluorescent microspheres can be adapted for rapid molecular profiling using intact platelets (bypassing the need for RNA isolation methods), with potential applicability irrespective of baseline platelet counts.

Keywords

mRNA, Platelets, transcript profiling, fluorescent microspheres, Luminex

DOI

http://dx.doi.org/10.1160/TH08-05-0305

You may also be interested in...

1.

E. Huang (1), W. Zhu (1), A. Dhundale (2, 3), W. F. Bahou (4, 5, 6), D. V. Gnatenko (4, 7, 2)

Thromb Haemost 2013 109 2: 337-346

http://dx.doi.org/10.1160/TH12-04-0257

2.

Online Supplementary Material

H. Plé (1, 2), M. Maltais (3), A. Corduan (1, 2), G. Rousseau (3), F. Madore (3), P. Provost (1, 2)

Thromb Haemost 2012 108 4: 605-615

http://dx.doi.org/10.1160/TH12-03-0153

3.

Sasidhar Guthikonda1, Kirankumar Mangalpally1, Muthiah Vaduganathan1, Rajnikant Patel2, Timothy DeLao1, Angela L. Bergeron3, Jing-Fei Dong3, Eli I. Lev1, Neal S. Kleiman1

Thromb Haemost 2008 100 1: 83-89

http://dx.doi.org/10.1160/TH07-10-0590



Thrombosis News

Mobile technology identifies people with unknown atrial fibrillation at high risk of stroke – article published in Thrombosis and Haemostasis

The article “Feasibility and cost effectiveness of stroke prevention through community screening...

TH 111.4

The April 2014 TH 111.4 issue of Thrombosis and Haemostasis is a Theme Issue by Guest Editor B....

TH 111.3

Women with atrial fibrillation have a much higher risk for thromboembolic stroke than men suffering...