Anzeige

Biomechanical comparison of the pullout properties of external skeletal fixation pins in the tibiae of intact and ovariectomised ewes

Journal:Veterinary and Comparative Orthopaedics and Traumatology (VCOT)
ISSN:0932-0814
DOI:http://dx.doi.org/10.3415/VCOT-07-09-0089
Issue:2008: Issue 5 2008
Pages:418-426

Biomechanical comparison of the pullout properties of external skeletal fixation pins in the tibiae of intact and ovariectomised ewes

B. J. Keeley1; B. Heidari2; N. J. Mahony3; S. M. Rackard1; F. J. O’Brien4, T. C. Lee3,4, O. Brennan4; O. D. Kennedy4; D. FitzPatrick2
1UCD School of Agriculture, Food Science and Veterinary Medicine, University College Dublin, Belfield, Dublin, Republic of Ireland; 2UCD School of Electrical, Electronic and Mechanical Engineering, Engineering and Material Sciences Centre, University College Dublin, Belfield, Dublin, Republic of Ireland; 3Trinity Centre for Bioengineering, Department of Mechanical Engineering, Trinity College, Dublin, Republic of Ireland; 4Department of Anatomy, Royal College of Surgeons in Ireland, Dublin, Republic of Ireland

Summary

The pin-bone interface is the least stable component of the external skeletal fixator. Concerns exist regarding the ability to obtain adequate implant purchase in poor quality bone. Consequently, reduced bone quality has been viewed as a contra-indication for the use of external skeletal fixators. The aim of this study was to investigate the holding power of two different fixator pin designs in bone from entire and ovariectomised sheep. Thirty-two aged ewes were divided into two groups. Group 1 were controls, and Group 2 were ovariectomised (OVX). The ewes were sacrificed 12 months postovariectomy and five pairs of tibiae were harvested from each group. The holding power of cortical and cancellous fixator pins was assessed at five standardised locations on each tibia. An increase in mean cortical thickness was noted in the OVX group. The holding power of cancellous fixator pins was superior to that of cortical pins, irrespective of whether or not ovariectomy had been performed. Cancellous pins had an increased holding power in post ovariectomy bone compared to control bone. Cortical pin performance was not affected by ovariectomy. There was a lack of correlation between the incidence of insertional fractures of the far cortex and implant holding power. The results raise questions over the effectiveness of ovariectomy in establishing osteopaenic bone suitable for assessing implant performance, hence further investigations are warranted.

Keywords

cancellous, Implant, holding power, mechanical properties, cortical

DOI

http://dx.doi.org/10.3415/VCOT-07-09-0089

You may also be interested in...

1.

K. A. Mann (1), M. A. Miller (1), M. Khorasani (1), K. L. Townsend (2), M. J. Allen (2)

VCOT - Veterinary and Comparative Orthopaedics and Traumatology 2012 25 1: 1-10

http://dx.doi.org/10.3415/VCOT-11-01-0014

2.

J. Bokemeyer (1), A. Fischer (1), M. Sadan (2), M. Kramer (1), M. Gerwing (1)

Tierärztliche Praxis Kleintiere 2011 39 1: 7-16

3.

K. G. Mathews (1), A. Danova (1), H. Newman (3), H. J. Barnes (2), L. Phillips (4)

VCOT - Veterinary and Comparative Orthopaedics and Traumatology 2003 16 1: 50-



Articles

You've 898 Article(s) in your Basket.

VCOT 3/2012

Synoviocentesis of the equine digital flexor tendon. In issue 3/2012 of VCOT, Jordana et al. give...

VCOT 2/2012

The need for revision in non-cemented total hip implants is a growing problem in people who are...

VCOT 1/2012

Cranial cruciate ligament rupture is one of the most common conditions affecting the stifle joint...