Anzeige

A device for performing whole bone torsional testing in a single-axis linear motion testing machine

Journal:Veterinary and Comparative Orthopaedics and Traumatology (VCOT)
ISSN:0932-0814
DOI:http://dx.doi.org/10.3415/VCOT-07-10-0091
Issue:2008: Issue 5 2008
Pages:478-480

A device for performing whole bone torsional testing in a single-axis linear motion testing machine

J. M. Tyler1; W. Larinde2; S. H. Elder2
1Department of Biological Sciences, New Jersey Institute of Technology, Newark, New Jersey, USA; 2Agricultural & Biological Engineering Department, Mississippi State University, Starkville, Mississippi, USA

Summary

Objectives: To design a device for the conversion of linear to rotational motion and to use it in order to determine torsional properties of canine tibiae in a universal tension/compression testing machine. Methods: A fixture incorporating a cable and pulley at one end and a guide block and rail assembly at the other was used to test 10 whole canine tibiae to failure in torsion at 1º/s. Results: The device produced spiral fractures in all tibiae. Torsional strength and stiffness were 13.9 ± 1.4 N m and 0.53 ± 0.07 N m/degree, respectively. Clinical significance: This inexpensive device can be used to evaluate the mechanical properties of long bones after various interventions to improve fracture healing. The device can be adapted for use with any single-axis linear motion testing machine. Assessment of fracture healing often includes loading to failure in torsion (1–5). Torsional testing is typically performed using a biaxial servohydraulic testing machine or similar sophisticated electromechanical equipment. Due to its high cost, many researchers do not have such equipment at their disposal. However, uniaxial tension-compression testing machines are widely available. Therefore, a device that can be used to perform torsional testing in a tension-compression machine would be beneficial. In this study we present a custom fixture for converting the vertical linear motion of a universal testing machine to rotational motion and validate its performance in torsional testing of canine tibiae.

Keywords

torsion, testing fixture, whole bone biomechanics

DOI

http://dx.doi.org/10.3415/VCOT-07-10-0091

You may also be interested in...

1.

Erratum in Issue 1 2012

J. B. Cabassu (1), M. P. Kowaleski (1), J. K. Shorinko (2), C. A. Blake (1), G. R. Gaudette (2), R. J. Boudrieau (1)

VCOT - Veterinary and Comparative Orthopaedics and Traumatology 2011 24 6: 418-425

http://dx.doi.org/10.3415/VCOT-11-04-0050

2.

K. M. Thieman (1), A. Pozzi (1)

VCOT - Veterinary and Comparative Orthopaedics and Traumatology 2010 23 4: 259-261

http://dx.doi.org/10.3415/VCOT-09-10-0111

3.

D. R. Mason (1), K. S. Schulz (2), P. H. Kass (3), S. M. Stover (4)

VCOT - Veterinary and Comparative Orthopaedics and Traumatology 2003 16 4: 238-



Articles

You've 895 Article(s) in your Basket.

VCOT 3/2012

Synoviocentesis of the equine digital flexor tendon. In issue 3/2012 of VCOT, Jordana et al. give...

VCOT 2/2012

The need for revision in non-cemented total hip implants is a growing problem in people who are...

VCOT 1/2012

Cranial cruciate ligament rupture is one of the most common conditions affecting the stifle joint...