Advertisement



Please note that all articles available in PrePrint Online are not necessarily the final, author corrected version of the paper. For more information on PrePrint Online, click here.

Articles prepublished January 27, 2012

Development of a femoral stem providing strong anchorage and facilitated removal

Journal:Veterinary and Comparative Orthopaedics and Traumatology (VCOT)
ISSN:0932-0814
DOI:http://dx.doi.org/10.3415/VCOT-11-02-0032
Issue:2012: Issue 2 2012
Pages:95-101

Development of a femoral stem providing strong anchorage and facilitated removal

An experimental study in goats

K. Harboe (1), C. H. Enoksen (1), N. R. Gjerdet (2), E. Sudmann (3)

(1) Stavanger University Hospital, Orthopaedic Department, Stavanger, Norway; (2) University of Bergen, Department of Clinical Dentistry, Faculty of Medicine and Dentistry, Bergen, Norway; (3) University of Bergen, Department of Surgical Sciences, Bergen, Norway

Summary

Objective: Prosthetic elements must be securely anchored to bone. Should revision surgery be necessary, preservation of bone stock is crucial. The goal of this study was to develop and assess a femoral stem combining secure anchorage and facilitated removal in a goat model. Methods: The development of the uncemented femoral stem was part of an innovation process to fulfill the combined requirements. The stem was designed with two longitudinal semicircular grooves to accommodate a drill bit to unanchor the stem. These grooves were interconnected by canals, each 1 mm in diameter. The surface was partly coated with hydroxyapatite (HA). The stems were inserted in the left hip of 35 goats. Perioperatively, the grooves were filled with autologous bone grafts, and standard cemented canine acetabular component and head were used. The pull-out force was measured six months postoperatively. Following randomization, 11 animals had the grooves of the stem drilled to remove anchoring tissue. Twelve animals were left undrilled (controls). Results: There was a significant difference in mean pull-out force between the group that had been drilled (1526 N) compared with the controls (2033 N, p = 0.028). Most of the HA had been resorbed. Clinical significance: The stems had a high retention force. The procedure for un-anchoring by drilling significantly reduced the pull-out force.

Keywords

total hip replacement, uncemented, goat, Experimental, Stem extraction

DOI

http://dx.doi.org/10.3415/VCOT-11-02-0032

You may also be interested in...

1.

Kathrin Hochmuth, Stefan Rehart

arthritis + rheuma 2004 24 5: 143-147

2.

S. Meinecke-Tillmann, B. Meinecke

Tierärztliche Praxis Großtiere 2008 36 2: 86-94

3.

K. Thies1, B. Jacobsen2, A. von Altrock1, Ch. Förster3, W. Baumgärtner2, M. Ganter1

Tierärztliche Praxis Großtiere 2008 36 1: 20-26